トップ «前の日記(2008-01-13(日)) 最新 次の日記(2008-01-15(火))» 編集

とた日記


2008-01-14(月) 晴 安静時心拍数 57 [長年日記]

_ 成人の日(1)

今年もどんなバカ成人が登場するか楽しみですな。

_ HDDの検査(1)

念のためHDDの検査をしておきます。

S.M.A.R.T機能の有効化

# smartctl -s on /dev/ad6
smartctl version 5.37 [i386-portbld-freebsd7.0] Copyright (C) 2002-6 Bruce Allen
Home page is http://smartmontools.sourceforge.net/
 
=== START OF ENABLE/DISABLE COMMANDS SECTION ===
SMART Enabled.
 

ヘルス情報の表示

# smartctl -H /dev/ad6
smartctl version 5.37 [i386-portbld-freebsd7.0] Copyright (C) 2002-6 Bruce Allen
Home page is http://smartmontools.sourceforge.net/
 
=== START OF READ SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED
 

全S.M.A.R.T情報の表示

# smartctl -a /dev/ad6
smartctl version 5.37 [i386-portbld-freebsd7.0] Copyright (C) 2002-6 Bruce Allen
Home page is http://smartmontools.sourceforge.net/
 
=== START OF INFORMATION SECTION ===
Model Family:     Seagate Barracuda 7200.7 and 7200.7 Plus family
Device Model:     ST3160023AS
Serial Number:    3JS1MXS3
Firmware Version: 3.05
User Capacity:    160,041,885,696 bytes
Device is:        In smartctl database [for details use: -P show]
ATA Version is:   6
ATA Standard is:  ATA/ATAPI-6 T13 1410D revision 2
Local Time is:    Mon Jan 14 14:37:38 2008 JST
SMART support is: Available - device has SMART capability.
SMART support is: Enabled
 
=== START OF READ SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED
 
General SMART Values:
Offline data collection status:  (0x82)	Offline data collection activity
					was completed without error.
					Auto Offline Data Collection: Enabled.
Self-test execution status:      (   0)	The previous self-test routine completed
					without error or no self-test has ever 
					been run.
Total time to complete Offline 
data collection: 		 ( 430) seconds.
Offline data collection
capabilities: 			 (0x5b) SMART execute Offline immediate.
					Auto Offline data collection on/off support.
					Suspend Offline collection upon new
					command.
					Offline surface scan supported.
					Self-test supported.
					No Conveyance Self-test supported.
					Selective Self-test supported.
SMART capabilities:            (0x0003)	Saves SMART data before entering
					power-saving mode.
					Supports SMART auto save timer.
Error logging capability:        (0x01)	Error logging supported.
					No General Purpose Logging support.
Short self-test routine 
recommended polling time: 	 (   1) minutes.
Extended self-test routine
recommended polling time: 	 ( 111) minutes.
 
SMART Attributes Data Structure revision number: 10
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME          FLAG     VALUE WORST THRESH TYPE      UPDATED  WHEN_FAILED RAW_VALUE
  1 Raw_Read_Error_Rate     0x000f   063   057   006    Pre-fail  Always       -       63768175
  3 Spin_Up_Time            0x0003   096   096   000    Pre-fail  Always       -       0
  4 Start_Stop_Count        0x0032   100   100   020    Old_age   Always       -       1
  5 Reallocated_Sector_Ct   0x0033   100   100   036    Pre-fail  Always       -       0
  7 Seek_Error_Rate         0x000f   086   060   030    Pre-fail  Always       -       447956888
  9 Power_On_Hours          0x0032   093   093   000    Old_age   Always       -       6930
 10 Spin_Retry_Count        0x0013   100   100   097    Pre-fail  Always       -       0
 12 Power_Cycle_Count       0x0032   099   099   020    Old_age   Always       -       1212
194 Temperature_Celsius     0x0022   039   058   000    Old_age   Always       -       39
195 Hardware_ECC_Recovered  0x001a   063   056   000    Old_age   Always       -       63768175
197 Current_Pending_Sector  0x0012   100   100   000    Old_age   Always       -       0
198 Offline_Uncorrectable   0x0010   100   100   000    Old_age   Offline      -       0
199 UDMA_CRC_Error_Count    0x003e   200   200   000    Old_age   Always       -       0
200 Multi_Zone_Error_Rate   0x0000   100   253   000    Old_age   Offline      -       0
202 TA_Increase_Count       0x0032   100   253   000    Old_age   Always       -       0
 
SMART Error Log Version: 1
No Errors Logged
 
SMART Self-test log structure revision number 1
No self-tests have been logged.  [To run self-tests, use: smartctl -t]
 
 
SMART Selective self-test log data structure revision number 1
 SPAN  MIN_LBA  MAX_LBA  CURRENT_TEST_STATUS
    1        0        0  Not_testing
    2        0        0  Not_testing
    3        0        0  Not_testing
    4        0        0  Not_testing
    5        0        0  Not_testing
Selective self-test flags (0x0):
  After scanning selected spans, do NOT read-scan remainder of disk.
If Selective self-test is pending on power-up, resume after 0 minute delay.
 

お試しに短く

# smartctl -t short /dev/ad6
smartctl version 5.37 [i386-portbld-freebsd7.0] Copyright (C) 2002-6 Bruce Allen
Home page is http://smartmontools.sourceforge.net/
 
=== START OF OFFLINE IMMEDIATE AND SELF-TEST SECTION ===
Sending command: "Execute SMART Short self-test routine immediately in off-line mode".
Drive command "Execute SMART Short self-test routine immediately in off-line mode" successful.
Testing has begun.
Please wait 1 minutes for test to complete.
Test will complete after Mon Jan 14 14:50:34 2008
 
Use smartctl -X to abort test.

1分後

# date
Mon Jan 14 14:51:09 JST 2008
# smartctl -l selftest /dev/ad6
smartctl version 5.37 [i386-portbld-freebsd7.0] Copyright (C) 2002-6 Bruce Allen
Home page is http://smartmontools.sourceforge.net/
 
=== START OF READ SMART DATA SECTION ===
SMART Self-test log structure revision number 1
Num  Test_Description    Status                  Remaining  LifeTime(hours)  LBA_of_first_error
# 1  Short offline       Completed without error       00%      6930         -
 

今のところ問題なさげです。差し当たり緊急の用も無いのでlongを実行してみます。

# smartctl -t long /dev/ad6
smartctl version 5.37 [i386-portbld-freebsd7.0] Copyright (C) 2002-6 Bruce Allen
Home page is http://smartmontools.sourceforge.net/
 
=== START OF OFFLINE IMMEDIATE AND SELF-TEST SECTION ===
Sending command: "Execute SMART Extended self-test routine immediately in off-line mode".
Drive command "Execute SMART Extended self-test routine immediately in off-line mode" successful.
Testing has begun.
Please wait 111 minutes for test to complete.
Test will complete after Mon Jan 14 16:51:30 2008
 
Use smartctl -X to abort test.

今、実行中です。結果はあとで。

_ <自転車>福島晋一・康司兄弟がタイで2日連続の挙式

「井上康生と東原亜希が結婚」というどうでもいいタイトルにつられてスポーツ欄を眺めていて発見しました。ジャパンカップ前夜祭で、ビールOまえ師匠も取材に行くと言っていたので今日あたりは帰国の途についているのかなぁと思ったら、

自転車ロードレースの国内強豪選手として知られる福島康司(34=梅丹本舗GDR)が、1月11日にタイ北部のチェンライにあるホテル・モンファーサイで、沖縄在住時代の幼なじみ、大城美林さんとの結婚披露宴を行った。当地では梅丹本舗のチームメート、日本からの知人やファンをはじめ、タイや台湾、マレーシアなどからの知人が多数列席し、2人の門出を心から祝福した。

 翌12日には兄の晋一(36=梅丹本舗GDR)と地元女性のアンさんの結婚披露宴が行われ、13日には結婚を祝って200kmを超える長距離サイクリングが開催される予定だ。(大前仁)

[<自転車>福島晋一・康司兄弟がタイで2日連続の挙式(サイクルスタイル・ドットネット) - Yahoo!ニュースより引用]

ビールOまえ師匠が書いた記事でした。

_ HDDの検査(2)

さっきの結果です。

# date
Mon Jan 14 16:58:56 JST 2008
# smartctl -l selftest /dev/ad6
smartctl version 5.37 [i386-portbld-freebsd7.0] Copyright (C) 2002-6 Bruce Allen
Home page is http://smartmontools.sourceforge.net/
 
=== START OF READ SMART DATA SECTION ===
SMART Self-test log structure revision number 1
Num  Test_Description    Status                  Remaining  LifeTime(hours)  LBA_of_first_error
# 1  Extended offline    Completed without error       00%      6931         -
# 2  Short offline       Completed without error       00%      6930         -
 

今のところ問題なさげです。